1.
Abstract

A real-time monitoring methodology to determine diesel fine particles in diesel emissions has been evaluated. The range of particle size captured by the monitor was ~0.1 μm to 1 μm. DustTrak real-time monitors were connected to the dilution tunnel of the vehicle exhaust to measure the emissions during the vehicle tests under both dynamic and steady-state driving conditions, and concentration data were recorded every 5 sec. Test variation of the real-time monitoring among different test days was similar to that measured by traditional filter-based gravi-metric method, whereas the repeatability of the monitor data within the same-day tests was better than that of gravimetric method. Correlations between the two methods were established for different fuels tested on a single light duty vehicle. When the emissions from the reference fuel was used to convert the monitor’s response to diesel fuels, the levels determined by the real-time monitor were consistent with those measured by gravimetric method among different fuels tested. Use of the real-time monitor could provide information on the levels of fine particles that is more relevant to the public health than the total particles.  相似文献   
2.
When using stable enzyme genes from a thermophile to create a biosensor in Escherichia coli, it is vital that these genes be overexpressed in order to provide a sufficient supply of enzymes. In this study, overexpression of the NADH oxidase (Nox) gene from the thermophile Deinococcus geothermalis was successfully achieved with the aim of creating a stable biosensor active at room temperatures. To do so, modification of 10 nucleotides, GAAATTAACT, upstream of the start codon of the Nox gene was necessary.  相似文献   
3.
When using stable enzyme genes from a thermophile to create a biosensor in Escherichia coli, it is vital that these genes be overexpressed in order to provide a sufficient supply of enzymes. In this study, overexpression of the NADH oxidase (Nox) gene from the thermophile Deinococcus geothermalis was successfully achieved with the aim of creating a stable biosensor active at room temperatures. To do so, modification of 10 nucleotides, GAAATTAACT, upstream of the start codon of the Nox gene was necessary.  相似文献   
4.
To investigate particle characteristics and find an effective measure to control severe particle pollution, year-round observation of size-segregated inorganic aerosols was conducted in Beijing from January to December, 2016. The sampled atmospheric particles all presented bimodal size distribution at four pollution levels (clear, slight pollution, moderate pollution and severe pollution), and peak values appeared at the size range of 0.7-2.1 μm and >9.0 μm, respectively. As dominant particle compositions, NO3, SO42−, and NH4+ in four pollution levels all showed significant peaks in fine mode, especially at the size range of 1.1-2.1 μm. Secondary inorganic aerosols accounted for about 67.6% (36.3% (secondary sulfates) + 31.3% (secondary nitrates)) of the total sources of fine particles in urban Beijing. Severe pollution of fine particles was mainly caused by the air masses transported from nearby western and southern areas, which are industrial and densely populated region, respectively. Sensitivity tests further revealed that the control measures focusing on ammonium emission reduction was the most effective for particle pollution mitigation, and fine particles all showed nonlinear responses after reducing ammonium, nitrate, and sulfate concentrations, with the fitting curves of y = -120.8x - 306.1x2 + 290.2x3, y = -43.5x - 67.8x2, and y = -25.8x - 110.4x2 + 7.6x3, respectively (y and x present fine particle mass variation (μg/m3) and concentration reduction ratio (CRR)/100 (dimensionless)). Overall, our study presents useful information for understanding the characteristics of atmospheric inorganic aerosols in urban Beijing, as well as offers policy makers with effective measure for mitigating particle pollution.  相似文献   
5.
6.
Activated carbons were prepared from cattle manure compost (CMC) by ZnCl2 activation with various ZnCl2/CMC mass ratios. Based on the N2 adsorption-desorption isotherms, mathematical models including the Dubinin-Radushkevich (DR) equation, the αs plot, and the Horvath-Kawazoe method were used to analyze the pore structural characteristics of the prepared activated carbons. It was found that for carbons possessing both micro-and mesopores, the DR method provided a more accurate estimation than the αs method for the extent of microporosity. The effect of the ZnCl2 impregnation ratio on the pore structure was discussed using the DR method. The results revealed that pore evolution involved three distinct regions with increases in the amount of impregnated ZnCl2: raising the ZnCl2/CMC mass ratio from 0.00 to 0.50 resulted in a 19-fold increase in micropore volume (Vme D) but caused no change in the mesopore volume (Vme D); increasing the ZnCl2/CMC mass ratio from 0.50 to 1.00 led to an increment in Vmi D of about 50% and in Vme D of 170%; while raising the ratio from 1.50 to 2.50 caused a slight decrease in Vmi D but a 200% increment in the value of Vme D.  相似文献   
7.
Concentrations of total mercury were determined by cold-vapour atomic absorption spectroscopy (CV-AAS) in 221 caps and 221 stalks of 15 species of wild growing higher fungi/mushrooms and 221 samples of corresponding soil substrate collected in 1997-98 in Manowo County, near the city of Koszalin in North-central Poland. Mean mercury concentrations in caps and stalks of the mushroom species examined and soils varied between 30+/-31 and 920+/-280, 17+/-11 and 560+/-220, and 10+/-9 and 170+/-110 ng/g dry matter, respectively. Cap to stalk mercury concentration quotients were from 1.0+/-0.4 in poison pax (Paxillus involutus) to 2.8+/-0.7 in slippery jack (Suillus luteus). Brown cort (Cortinarius malicorius), fly agaric (Amanita muscaria), orange-brown ringless amanita (A. fulva), red-aspen bolete (Leccinum rufum) and mutagen milk cap (Lactarius necator) contained the highest concentrations of mercury both in caps and stalks, and mean concentrations varied between 600+/-750 and 920+/-280 and 370+/-470 and 560+/-220 ng/g dry matter, respectively. An estimate of daily intake of mercury from mushroom consumption indicated that the flesh of edible species of mushrooms may not pose hazards to human health even at a maximum consumption rate of 28 g/day. However, it should be noted that mercury intake from other foods will augment the daily intake rates. Species such as the sickener (Russula emetica), Geranium-scented russula (R. fellea) and poison pax (P. involutus) did not concentrate mercury as evidenced from the bioconcentration factors (BCFs: concentrations in mushroom/concentration in soil substrate), which were less than 1. Similarly, red-hot milk cap (L. rufus), rickstone funnel cap (Clitocybe geotropa) and European cow bolete (S. bovinus) were observed to be weak accumulators of mercury. Fly agaric (A. muscaria) accumulated great concentrations of mercury with BCFs reaching 73+/-42 and 38+/-22 in caps and stalks, respectively. Mercury BCFs of between 4.0+/-2.3 and 23+/-25 (caps) and 2.6+/-1.9 and 14+/-12 (stalks) were noted for the other mushroom species. Relatively great concentrations of mercury in fly agaric (A. muscaria) were due to preferential uptake of this element by this species.  相似文献   
8.
A modified thermal desorption method to determine low levels of aniline and other related mono-aromatic amines (MAAs) in residential air is described. The method was successfully applied to the determination of levels of these chemicals in residential air from 69 selected homes in two Canadian regions. Instrument detection limits of between 0.02 and 0.06 ng per thermal desorption tube were achieved for aniline and other MAAs. In the absence of environmental tobacco smoke (ETS) the mean concentrations of aniline in both indoor air and outdoor air were similar, at about 0.01 microgram/m3 after correction with field blanks. There was however a statistically significant difference in aniline concentrations between field blanks and indoor or outdoor air samples. No significant difference of aniline levels in the two study regions was observed. A clear link between aniline concentrations in indoor air and smoking activities inside homes was evident. Analysis of cigarette leaves indicated that aniline was most likely formed due to combustion during smoking. Shoe polishing was identified as another source of aniline in indoor air.  相似文献   
9.
Dioxin concentrations from municipal waste incinerators in Japan and elsewhere often show low concentrations that comply with legal limits (in this paper, the term "dioxin" designates WHO-TEQ: PCDD/Fs+dioxin-like PCB). However, such data is usually generated under normal steady state operational conditions, and there has been little investigation of releases occurring during startup and shutdown. It is important, therefore, to ascertain quantitatively emissions in an unsteady state (startup and shutdown) in order to correctly evaluate the relationship between emissions from a facility and the surrounding environment. The present study aimed to examine dioxin emissions of a continuously operated incinerator at startup and shutdown, and estimating the time period of greatest emission, and the processes causing dioxin generation. The startup process was divided into five stages and the shutdown into two; at each stage, dioxins in the flue gas were measured at the boiler outlet and the stack. From the concentration of dioxins and the flue gas volume at each stage, the amount of dioxins at startup and shutdown were calculated, and these were compared with that under steady state conditions. Dioxin concentration at the stack under steady state conditions was a very low level, while those at startup and shutdown were higher. In the case where dioxin concentration under a steady state is a low level like in this study, it is indicated that the total annual dioxin emission from a facility could be attributed to the startup periods.  相似文献   
10.
The atmospheric condition in an urbanized area of Japan was examined from the viewpoint of a 14-year trend in the rainfall intensity. To cancel the wide-area meteorological phenomena such as a typhoon and a front, the rainfall datasets obtained not only in an urban area but also in a rural area was studied. The rainfall datasets collected on a 0.5 mm rainfall basis was used. The rainfall intensity dominantly increased in urban area, while that in rural area neither increased nor decreased. An increasing trend was clearly observed for rainfall with precipitation amounts of 5 and 10 mm. Rainfall with precipitation amounts of 15 and 20 mm showed neither an increasing nor a decreasing trend. The results of this study show that there is a high probability of a connection between the urbanization and the change of rainfall intensity.  相似文献   